Rooftop Solar · Shopping Centre · Bethal, Mpumalanga
Bethal Mall




The project
The system covers a significant area of the mall's rooftop, providing daytime energy to reduce municipal electricity costs. The system is integrated with the mall's generators, which supply the centre during grid outages. The system includes a 25-year maintenance agreement with 24/7 remote monitoring.
Energy to date
3.61 million kWh generated since February 2022.
- Generated, Feb 2022 to Oct 2026
- 3,617,992 kWh
- Monthly reports on record
- 57
- Highest month, October 2026
- 99,853 kWh
- February 2022: 61,740 kWh.
- March 2022: 59,964 kWh.
- April 2022: 48,449 kWh.
- May 2022: 46,559 kWh.
- June 2022: 49,682 kWh.
- July 2022: 46,170 kWh.
- August 2022: 64,020 kWh.
- September 2022: 53,882 kWh.
- October 2022: 67,755 kWh.
- November 2022: 61,552 kWh.
- December 2022: 67,495 kWh.
- January 2023: 82,642 kWh.
- February 2023: 58,920 kWh.
- March 2023: 62,620 kWh.
- April 2023: 57,344 kWh.
- May 2023: 39,040 kWh.
- June 2023: 44,831 kWh.
- July 2023: 45,305 kWh.
- August 2023: 65,775 kWh.
- September 2023: 63,780 kWh.
- October 2023: 80,910 kWh.
- November 2023: 73,008 kWh.
- December 2023: 84,973 kWh.
- January 2024: 88,141 kWh.
- February 2024: 74,605 kWh.
- March 2024: 75,944 kWh.
- April 2024: 61,636 kWh.
- May 2024: 54,648 kWh.
- June 2024: 39,732 kWh.
- July 2024: 44,570 kWh.
- August 2024: 68,453 kWh.
- September 2024: 62,983 kWh.
- October 2024: 87,930 kWh.
- November 2024: 89,920 kWh.
- December 2024: 73,688 kWh.
- January 2025: 91,064 kWh.
- February 2025: 70,174 kWh.
- March 2025: 70,411 kWh.
- April 2025: 56,612 kWh.
- May 2025: 65,344 kWh.
- June 2025: 51,099 kWh.
- July 2025: 54,418 kWh.
- August 2025: 70,973 kWh.
- September 2025: 66,011 kWh.
- October 2025: 76,591 kWh.
- November 2025: 35,103 kWh.
- December 2025: 56,216 kWh.
- January 2026: 85,681 kWh.
- February 2026: 70,702 kWh.
- March 2026: 56,887 kWh.
- April 2026: 47,522 kWh.
- May 2026: 48,714 kWh.
- June 2026: 45,647 kWh.
- July 2026: 53,382 kWh.
- August 2026: 68,193 kWh.
- September 2026: 68,729 kWh.
- October 2026: 99,853 kWh.
Show the figures
| Year | Reports | Generated (kWh) |
|---|---|---|
| 2022 | 11 | 627,268 |
| 2023 | 12 | 759,148 |
| 2024 | 12 | 822,250 |
| 2025 | 12 | 764,016 |
| 2026 | 10 | 645,310 |
| Total | 57 | 3,617,992 |
| Month | Generated (kWh) |
|---|---|
| February 2022 | 61,740 |
| March 2022 | 59,964 |
| April 2022 | 48,449 |
| May 2022 | 46,559 |
| June 2022 | 49,682 |
| July 2022 | 46,170 |
| August 2022 | 64,020 |
| September 2022 | 53,882 |
| October 2022 | 67,755 |
| November 2022 | 61,552 |
| December 2022 | 67,495 |
| January 2023 | 82,642 |
| February 2023 | 58,920 |
| March 2023 | 62,620 |
| April 2023 | 57,344 |
| May 2023 | 39,040 |
| June 2023 | 44,831 |
| July 2023 | 45,305 |
| August 2023 | 65,775 |
| September 2023 | 63,780 |
| October 2023 | 80,910 |
| November 2023 | 73,008 |
| December 2023 | 84,973 |
| January 2024 | 88,141 |
| February 2024 | 74,605 |
| March 2024 | 75,944 |
| April 2024 | 61,636 |
| May 2024 | 54,648 |
| June 2024 | 39,732 |
| July 2024 | 44,570 |
| August 2024 | 68,453 |
| September 2024 | 62,983 |
| October 2024 | 87,930 |
| November 2024 | 89,920 |
| December 2024 | 73,688 |
| January 2025 | 91,064 |
| February 2025 | 70,174 |
| March 2025 | 70,411 |
| April 2025 | 56,612 |
| May 2025 | 65,344 |
| June 2025 | 51,099 |
| July 2025 | 54,418 |
| August 2025 | 70,973 |
| September 2025 | 66,011 |
| October 2025 | 76,591 |
| November 2025 | 35,103 |
| December 2025 | 56,216 |
| January 2026 | 85,681 |
| February 2026 | 70,702 |
| March 2026 | 56,887 |
| April 2026 | 47,522 |
| May 2026 | 48,714 |
| June 2026 | 45,647 |
| July 2026 | 53,382 |
| August 2026 | 68,193 |
| September 2026 | 68,729 |
| October 2026 | 99,853 |
We monitor the plant and report to its owner monthly. Each bar is the output printed on that month’s report, as it happened: months when the grid was down or an inverter was out for repair are included, not smoothed over.
Source: the plant’s monthly operations and maintenance reports, 57 on record, figures checked on 17 November 2026.
Technical Specifications
The plant in figures.
- System Capacity
- 641.5 kWp
- Panel Brand
- JA Solar 540W
- Inverters
- 5 × GoodWe 120kW
- Annual Production (design estimate)
- 1,025,973 kWh/year
- Yield (kWh/kWp, design)
- 1,599.3
- Solar Panels
- 1,188 solar panels
- Location
- Bethal, Mpumalanga
- Commissioned
- 1 February 2022
Included.
- Generator Integration
- Production Guarantee
- 25-Year Maintenance Agreement
- 24/7 Remote Monitoring
- Preventive Maintenance
- Performance Reporting
A system like Bethal Mall, designed for your site
Bethal Mall is a real 641.5 kWp rooftop solar installation we delivered in Bethal. We can structure something similar for your business — funded, capex or hybrid.
18.2MW
under O&M across 28 installations
20MW+
built since 2010
ECB licensed
SAAEA member
Since 2010